What is duct access panel installation in Tayside and North East Scotland?

Book duct access panel installation in Tayside and North East Scotland with a free survey, a fixed written quote and a TR19® Grease report at the end.

Duct access panel installation adds the openings that make ductwork cleanable. Many kitchen systems were installed with too few access points, so lengths of duct cannot be cleaned or tested. We fit grease-tight access doors at the spacing TR19® Grease expects.

Busy Tayside and North East Scotland kitchens often run fryers and grills for long hours. That puts them in the heavy-use band, where grease builds quickly and cleaning every three months is the TR19® Grease minimum.

What's included

  • Access survey marked on the duct schematic
  • Grease-tight hinged or bolted panels
  • Panels sized to the duct
  • Gaskets suitable for kitchen extract
  • Positions labelled for future cleans
  • Updated schematic on the report

Guide price

Usually £75 to £150 per panel fitted, depending on duct size and access. Every job is quoted in writing after a survey.

AreaTayside and North East Scotland, Scotland
RegionNorth East Scotland
Postcode areasAB, DD, IV
Towns listed9

Towns we cover in Tayside and North East Scotland

Nearby areas

Questions we're often asked

Do you provide duct access panel installation across Tayside and North East Scotland?

Yes. We cover Tayside and North East Scotland including Dundee, Aberdeen, Arbroath, Montrose, Forfar, with cleans booked around your opening hours.

How far apart should access panels be?

TR19® Grease sets spacings for horizontal and vertical runs and at changes of direction. We mark where panels are needed during the survey.

Can panels be fitted in fire-rated ductwork?

Fire-rated duct needs fire-rated access doors. We will tell you if this applies to your system.

Need a TR19® Grease clean or an insurer report?

Free survey, fixed written quote and cleans booked around your service.